The importance of Böhler’s Angle in Calcaneus Geometry: A Finite Element Model Study

dc.authorid0000-0002-0729-633Xen_US
dc.authorscopusid55292727500en_US
dc.contributor.authorGültekin, Alper
dc.contributor.authorAcar, Erdinç
dc.contributor.authorUğur, Levent
dc.contributor.authorYıldız, Aytaç
dc.contributor.authorSerarslan, Ulaş
dc.date.accessioned2022-04-21T06:03:36Z
dc.date.available2022-04-21T06:03:36Z
dc.date.issued2021en_US
dc.departmentBTÜ, Mühendislik ve Doğa Bilimleri Fakültesi, Endüstri Mühendisliği Bölümüen_US
dc.description.abstractObjectives: Calcaneal fractures are the most common tarsal fractures following a foot-ankle trauma. The Böhler’s angle is an important measurable angle before, during, and after surgery. In this study, we aimed to investigate correlation between Böhler’s angle, calcaneal strength, and subtalar joint stress using a finite element analysis (FEA). Patients and methods: Between January 2016 and December 2016, computed tomography (CT) scans were used with MIMICS® software for FEA. The ankle and foot of a 23-year-old male person with a height of 180 cm and weighing 80 kg was modeled as reference. Raw coronal CT images were obtained in Digital Imaging and Communications in Medicine format with the resolution of 512¥512 pixels and 0.3-mm slice intervals in 135 kV. The structures including tibia, fibula and 26 other bones (talus, calcaneus, cuboid, navicular, three cuneiforms, five metatarsals, and 14 components of phalanges), cartilage and ligamentous tissues were modeled to form ankle joint. After determining Böhler’s angle as 35 degrees for the reference model, a fracture line was created on calcaneus. Calcaneus was remodeled with the Böhler’s angle of 45, 40, 30, 25, 20, 10, and 0 degrees respectively. All models were transferred to ANSYS software for FEA and the loads on the lower extremities with normal posture were applied on models. Results: Analysis of all models based in the reference model revealed that maximum tension values on calcaneus increased, while the Böhler’s angle decreased, indicating a statistically significant difference. The decreased Böhler’s angle indicated statistically significantly higher maximum tension values (p=0.04). Action force in subtalar joint was evaluated by comparing with the forces in reference model. The increased Böhler’s angle was found to be associated with statistically significantly decreased amount of load on subtalar joint. The decreased Böhler’s angle was related to the statistically significantly increased amount of load on subtalar joint. Conclusion: Our study results suggest that decreased Böhler’s angle increases the possibility of subtalar arthrosis, although overcorrection of the Böhler’s angle seems not to increase the risk of subtalar arthrosis.en_US
dc.identifier.doi10.52312/jdrs.2021.81251en_US
dc.identifier.endpage427en_US
dc.identifier.issn26874784
dc.identifier.issue2en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage420en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12885/1917
dc.identifier.volume32en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.institutionauthorYıldız, Aytaç
dc.language.isoenen_US
dc.publisherTurkish Joint Diseases Foundationen_US
dc.relation.ispartofJoint Diseases and Related Surgeryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBiomechanicsen_US
dc.subjectBöhleren_US
dc.subjectcalcaneusen_US
dc.subjectfinite element analysisen_US
dc.subjectfractureen_US
dc.subjectsubtalar arthrosisen_US
dc.titleThe importance of Böhler’s Angle in Calcaneus Geometry: A Finite Element Model Studyen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
2021-32-2-420-427-eng.pdf
Boyut:
1.15 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: