Efficiency Optimization of PMSM-Type Elevator Machine: An Industrial Comparison
| dc.authorid | 0000-0002-2809-9896 | |
| dc.authorid | 0000-0001-6658-5169 | |
| dc.authorid | 0000-0002-1522-6868 | |
| dc.contributor.author | Soyaslan, Mucahit | |
| dc.contributor.author | Eldogan, Osman | |
| dc.contributor.author | Fenercioglu, Ahmet | |
| dc.contributor.author | Avsar, Yusuf | |
| dc.contributor.author | Ceylan, Nurdogan | |
| dc.contributor.author | Sarikaya, Muhammed Salih | |
| dc.date.accessioned | 2026-02-08T15:15:57Z | |
| dc.date.available | 2026-02-08T15:15:57Z | |
| dc.date.issued | 2025 | |
| dc.department | Bursa Teknik Üniversitesi | |
| dc.description.abstract | This study presents the design, modeling, and prototyping of an external rotor permanent magnet synchronous motor (ER-PMSM) specifically for elevator traction systems. The external rotor design aims to surpass the efficiency of conventional inner rotor gearless elevator traction motors. A commercially available 4 kW inner rotor permanent magnet synchronous motor (IR-PMSM) was selected for comparative analysis. Critical parameters, including stator tooth tip thickness, slot tip radius, slot height, stator yoke height, stator tooth thickness, and the number of turns per phase, were optimized to enhance efficiency. The artificial bee colony (ABC) algorithm was utilized for the first time to determine the optimal configuration of an external rotor PMSM. The prototype was fabricated and subjected to rigorous testing using a dedicated electrical motor test setup. Comparative results demonstrated a significant improvement in efficiency for the ER-PMSM over the IR-PMSM, with the efficiency increasing from 72.5% to 84.67% at nominal operating conditions. | |
| dc.description.sponsorship | Scientific and Technological Research Council of Turkiye (TUBITAK); Sakarya University [218M615, 017-50-02-017] | |
| dc.description.sponsorship | This research was funded by The Scientific and Technological Research Council of Turkiye (TUBITAK) and Sakarya University, grant numbers 218M615 and 017-50-02-017. | |
| dc.identifier.doi | 10.3390/machines13030173 | |
| dc.identifier.issn | 2075-1702 | |
| dc.identifier.issue | 3 | |
| dc.identifier.scopus | 2-s2.0-105001348133 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.uri | https://doi.org/10.3390/machines13030173 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12885/6059 | |
| dc.identifier.volume | 13 | |
| dc.identifier.wos | WOS:001452601500001 | |
| dc.identifier.wosquality | Q2 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.language.iso | en | |
| dc.publisher | Mdpi | |
| dc.relation.ispartof | Machines | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.snmz | WOS_KA_20260207 | |
| dc.subject | artificial bee colony | |
| dc.subject | efficiency | |
| dc.subject | elevator traction machine | |
| dc.subject | external rotor | |
| dc.subject | optimization | |
| dc.subject | PM synchronous motor | |
| dc.title | Efficiency Optimization of PMSM-Type Elevator Machine: An Industrial Comparison | |
| dc.type | Article |