Investigation of radiological properties and water equivalence of polymer gel dosimeters in the energy range 0.1-10 keV

dc.authorid0000-0002-2704-771X
dc.contributor.authorLevet, Aytac
dc.contributor.authorThakur, Sonika
dc.contributor.authorKaur, Parminder
dc.contributor.authorRafiei, Mustafa Mohammad
dc.contributor.authorParsaei, Sara
dc.contributor.authorBuyukyildiz, Mehmet
dc.date.accessioned2026-02-08T15:15:23Z
dc.date.available2026-02-08T15:15:23Z
dc.date.issued2025
dc.departmentBursa Teknik Üniversitesi
dc.description.abstractThe interaction parameters of radiation with matter are crucial for accurately determining radiation doses in diagnostic and treatment. This study examined the radiological features of normoxic polymer gels used to measure radiation doses. The mass attenuation coefficient (MAC), mass energy-absorption coefficient (MEAC), effective atomic number (Zeff), half value layer (HVL) and mean free path (MFP) for these samples were determined in the energy range of 0.1 keV-10 keV. Zeff was established using direct and interpolation methods. The largest discrepancy for Zeff between the methods was observed for water, with a 48 % difference in the energy range of 0.3 keV-0.5 keV. MACs of the samples were compared with Monte Carlo simulation results based on FLUKA 4-3.1 code. MAC results obtained with simulation showed good agreement with Hubbell, and the maximum and minimum differences between them were seen in the FAT sample as 8.31 % and 0.08 %, respectively. Additionally, dose rate, gamma constant, and air kerma values were calculated using mass energy absorption coefficients for all samples and their water equivalence was evaluated in the relevant energy range. It was observed that the samples with radiological water equivalence and air kerma values close to 1 were PAGAT, MAGIC, MAGAS, and MAGAT.
dc.identifier.doi10.1016/j.net.2024.103387
dc.identifier.issn1738-5733
dc.identifier.issue6
dc.identifier.scopus2-s2.0-105001078134
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.net.2024.103387
dc.identifier.urihttps://hdl.handle.net/20.500.12885/5759
dc.identifier.volume57
dc.identifier.wosWOS:001453979000001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherKorean Nuclear Soc
dc.relation.ispartofNuclear Engineering and Technology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzWOS_KA_20260207
dc.subjectNormoxic polymer gels
dc.subjectRadiological parameters
dc.subjectMonte Carlo simulation
dc.titleInvestigation of radiological properties and water equivalence of polymer gel dosimeters in the energy range 0.1-10 keV
dc.typeArticle

Dosyalar