Orhaneli Termik Santralinin eksergoekonomik ve eksergoçevresel analizi

dc.contributor.advisorKara, Yusufali
dc.contributor.authorDüzcan, Abdullah
dc.date.accessioned2024-11-05T17:46:49Z
dc.date.available2024-11-05T17:46:49Z
dc.date.issued2019
dc.departmentBTÜ, Lisansüstü Eğitim Enstitüsü, Makine Mühendisliği Ana Bilim Dalıen_US
dc.descriptionFen Bilimleri Enstitüsü, Makine Mühendisliği Ana Bilim Dalıen_US
dc.description.abstractBir sistemi değerlendirirken enerjetik olarak değerlendirmek yeterli değildir. Sistemde oluşan kayıpların yerini, miktarını belirlemek için ekserji analizi yapılmaktadır. Bu çalışmada Bursa Orhaneli Termik Santrali'nin enerji, ekserji, eksergoekonomik ve eksergoçevresel analizi yapılmıştır. Ekserji analizinde fiziksel ve kimyasal ekserji dikkate alınmış, potansiyel ve kinetik ekserjiler ihmal edişmiştir. Ekserji analizi ile sistem bileşenlerinin ekserji verimleri ve ekserji yıkımları hesaplanmıştır. En yüksek ve en düşük ekserji verimlerine sahip ekipmanlar %92,41 ile orta basınç türbini ve %8,89 ile kondenserdir. Ekserji analizi sonucuna göre, iyileştirme potansiyeli en yüksek eleman kondenser olarak belirlenmiştir. Eksergoekonomik analizde de SPECO metodu kullanılmış ve her ekserji akımına karşılık gelen maliyet değerleri hesaplanmıştır. Eksergoekonomik analiz sonucuna göre, yüksek basınç türbinine gönderilen buharın birim ekserji maliyeti ve ekserji maliyeti sırasıyla 22,19 $/GJ ve 28.264 $/h olarak hesaplanmıştır. Sistemde kullanılan her ekipmanın yaşam döngüsü analizi (LCA) yapılmıştır. Yaşam döngüsü analizinden alınan sonuçlar ekserji akımlarına aktarılarak eksergoçevresel analiz gerçekleştirilmiştir. Analiz sonucuna göre, çevreye en zararlı ekipman kondenser olarak tespit edilmiştir.en_US
dc.description.abstractWhen evaluating a system, it is not enough to evaluate it energetically. Exergy analysis is performed to determine the location and amount of losses in the system. In this study, energy, exergy, exergoeconomic and exergoenvironmental analysis of Bursa Orhaneli Thermal Power Plant were carried out. In exergy analysis, physical and chemical exergy were taken into consideration and potential and kinetic exergy were neglected. Exergy efficiency and exergy destructions of system components were calculated by exergy analysis. Equipments with the highest and lowest exergy yields are medium pressure turbines with 92.41% and condensers with 8.89%. According to the results of exergy analysis, the element with the highest improvement potential was determined as condenser. SPECO method was used in exergoeconomic analysis and cost values corresponding to each exergy flow were calculated. According to exergoeconomic analysis, unit exergy cost and exergy cost of steam sent to high pressure turbine were calculated as $ 22.19/GJ and $ 28,264/h, respectively. Life cycle analysis (LCA) of each equipment used in the system was performed. The results of the life cycle analysis were transferred to exergy flows and exergoenvironmental analysis was performed. According to the results of the analysis, the most harmful equipment to the environment was identified as a condenser.en_US
dc.identifier.endpage64en_US
dc.identifier.startpage1en_US
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=FgmkGchPKo23qQqBeqzVZtrISS84DahmozfdTjpN5hzqEy3jKGaPQNMN4V9MyU1Y
dc.identifier.urihttps://hdl.handle.net/20.500.12885/2882
dc.identifier.yoktezid567316en_US
dc.language.isotren_US
dc.publisherBursa Teknik Üniversitesien_US
dc.relation.publicationcategoryTezen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.snmzKA_20241105
dc.subjectEnerjien_US
dc.subjectEnergyen_US
dc.titleOrhaneli Termik Santralinin eksergoekonomik ve eksergoçevresel analizien_US
dc.title.alternativeExergoeconomic and exergoenvironmental analysis of Orhaneli Power Planten_US