Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • DSpace İçeriği
  • Analiz
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Mazmanci, Mehmet Ali" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Polycyclic aromatic hydrocarbons (PAHs) determined by pine needles and semipermeable membrane devices along an altitude profile in Taurus Mountains, Turkey
    (Springer Heidelberg, 2017) Turgut, Cafer; Mazmanci, Mehmet Ali; Mazmanci, Birgul; Yalcm, Melis; Kurt Karakuş, Perihan Binnur; Atatanir, Levent
    Polycyclic aromatic hydrocarbons (PAHs) were analyzed at different altitudes of Taurus Mountains in semipermeable membrane devices (SPMD) and in half-, one-and-ahalf-, and two-and-a-half-year-old pine needles. SPMDs were deployed for three different exposure periods: March to September (Summer), September to March (Winter), and March to March (whole year) at eight sites where needle samples were collected. The values of PAHs in needles were between 4.4 to 6066 pg g/fw in half-year-old, 7.2 to 111,115 pg g/fw in 1.5-year-old, and 9.7 to 85,335 pg g/fw in 2.5-year-old needles. Mass of PAHs collected by SPMDs varied from < MDL to 8060 ng/SPMD in winter, from 0.98 to 585 ng/SPMD in summer, and < MDL to 9360 ng/SPMD in whole year deployment, respectively. PAH profiles were dependent on the seasonal differences and locations. Roughly, clear decreasing trends with altitude were observed both wit h SPMD and needles for many individual and groups of PAHs except for the SPMD-summer short-time data. A cross-plot of Fluo/(Fluo+Pyr) vs Ant/(Ant+Phe) diagnostic ratios indicated grass/wood burning (possibly due to forest fires) in summer and petrogenic combustion in winter. Results of the study showed that SPMD and conifer needles are effective passive samplers to measure PAHs in the environment.

| Bursa Teknik Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Mimar Sinan Mahallesi Mimar, Sinan Bulvarı, Eflak Caddesi, No: 177, 16310, Yıldırım, Bursa, Türkiye
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez ayarları
  • Gizlilik politikası
  • Son Kullanıcı Sözleşmesi
  • Geri bildirim Gönder