Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • DSpace İçeriği
  • Analiz
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Cene, Gulay Arslan" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Biodegradability enhancement of landfill leachate nanofiltration concentrate using sequential and combined electrochemical processes
    (Elsevier, 2025) Yucel, Esra; Ozen, Irem; Cene, Gulay Arslan; Ilhan, Hilal; Guvenc, Senem Yazici; Can-Guven, Emine; Demir, Ahmet
    In this study, the treatment of landfill leachate nanofiltration concentrate (LNFC) was investigated using sequential (two distinct stages, one following the other) and combined (two mechanisms operating simultaneously in a single reactor) electrochemical processes. In the first stage, initial pH, applied current, and reaction time were optimized for individual processes: electro-oxidation (EO), peroxi-coagulation (PC), and electrochemical-peroxidation (EP). In the second stage, sequential (EO-PC, PC-EO, EO-EP, EP-EO) and combined (EO/PC, EO/EP) processes were applied with the optimal conditions determined in the first stage. Under optimum conditions (pH 5; applied current 1 A; reaction time 60 min), chemical oxygen demand (COD) removal efficiencies of 38.9 %, 42.1 %, and 53.1 % were obtained for the EO, PC, and EP processes, respectively. Enhanced COD removal was obtained by sequential processes, yielding removal rates of 65.6 % for EO-PC, 71.1 % for PC-EO, 78.3 % for EO-EP, and 83.6 % for EP-EO. The highest efficiencies were observed in the combined systems, with COD removals of 76.4 % for EO/PC and 89.1 % for EO/EP. The lowest specific energy consumption (SEC) was calculated as 31.2 kWh/kg COD for EP among the single processes, 41.0 kWh/kg COD for EP-EO among the sequential processes, and 47.5 kWh/kg COD for EO/EP among the combined processes. These findings suggest that EP-based systems require less energy than EO-based systems. The EO/EP process can be proposed as an alternative treatment for LNFC due to its compliance with the discharge standards (500 mg/L for COD for leachate) specified in the Water Pollution Control Regulation of T & uuml;rkiye and its relatively low SEC.

| Bursa Teknik Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Mimar Sinan Mahallesi Mimar, Sinan Bulvarı, Eflak Caddesi, No: 177, 16310, Yıldırım, Bursa, Türkiye
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2026 LYRASIS

  • Çerez ayarları
  • Gizlilik politikası
  • Son Kullanıcı Sözleşmesi
  • Geri bildirim Gönder